Phantom Cloud logo

Fully web-based digital quality assurance software for your Phantom XY.

Buy Now
Dental team member using the Phantom Cloud Phantom Analyzer screen to run daily dental X-ray quality assurance tests

The Complete Solution: Digitalize Your Processes

Phantom Cloud Phantom Analyzer screen listing panoramic and intraoral X-ray devices with run test buttons and pass or fail results
Phantom Cloud intraoral sensor test result showing a pass for a Schick 33 size 2 sensor, with analysis regions marked in green
Phantom Cloud testing history log of dated panoramic and intraoral QA tests with pass and fail results

Phantom Cloud delivers results that are consistent, and based on objective criteria. All testing is automatically done with the click of the button. No need for judgement calls from the test operator.

The Phantom Analyzer algorithm inspects up to 17 different parameters in less than 8 seconds from a Phantom image. Allows the operator to detect beam strength deviation, mechanical degradation and more.

All results are automatically logged for a period of 10 years. Testing reports including extended history and detailed test results are able to be generated to pdf export with the click of a button.

Supercharge Your DQA

Uniformity

The Phantom Analyzer Algorithm ensures that each sector of the image has similar magnification and color characteristics.

Beam Strength

The software checks the image for subtle tell-tale signs that the beam has weakened or is dangerously overproducing radiation.

Consistency

Multiple sub-zones in the image are analyzed to ensure that there is minimal artifacts and colors are consistent.

Mechanical Alignment

It is essential that the motor mechanism is aligned and rotating the head evenly and precisely for a panoramic scan.

Collimator Alignment

It is critical that the radiation produced in a panoramic machine is directed at the sensor plate and does not leak out into the patients body.

Sharpness

The diagnostic quality of an image is dependent on seeing transitions clearly and sharply. The algorithm automatically finds edges and calculates sharpness.

Symmetry

Particularly for panoramic machines it is essential that the left and right side are symmetrically aligned and balanced.

Noise Immunity

Detects unwanted noise and irregular patterns that could compromise diagnostic image clarity.

Geometric Accuracy

Verifies that anatomical structures are rendered at true proportions, catching distortions that could lead to misdiagnosis.

Manage Your Test Processes Efficiently

Customization

Phantom Cloud lets you configure a testing system that is tailor made for your office. Configure your devices and preferences seamlessly within the app.

Testing History

All results posted are stored and easily retrieved for a period of 10 years. View detailed results and retrieve images with the click of a button.

Generate Reports

Create exportable PDF test reports. Generate detailed single test reports or summary report over a time period.

Notifications

Phantom Cloud can be configured to alert you when a failed test result is posted so you can immediately take action. Alerts for missed tests are also available.

Digital X-Ray Logbook

Phantom Cloud dental X-ray logbook listing images by device, operator, time of test and retake reason

We’re excited to introduce a powerful new feature to Phantom Cloud: the Automated Digital X-Ray Logbook - designed to help clinics meet regulatory compliance with zero manual effort. This new enhancement allows dental clinics to automatically log every X-Ray taken throughout the day, fully aligned with ministry mandates.

Gone are the days of manually recording critical details like:    
•    Date and time of the exposure  
•    Type of X-Ray taken    
•    Name of the operator    
•    Whether the image had to be retaken, and why

Phantom Cloud will allow the operator of the X-Ray taken to enter the information into Phantom Cloud, creating a secure, time-stamped digital record for each exposure - reducing human error, saving administrative time, and eliminating paper-based logbooks entirely.

To meet long-term audit and regulatory requirements, all logs are securely stored for a full 10 years, easily accessible whenever needed for review or by surprise inspections. With Phantom Cloud, clinics can now maintain a complete digital history of radiographic activity - without lifting a pen.

Phantom Cloud retake reason selector with options such as patient movement, wrong positioning, cone cut and exposure errors

Q-Score: X-Ray Health at a Glance

Q-Score logo

With each DQA test performed using the Phantom XY System, your equipment receives a Q-Score - a clear, easy-to-understand performance rating that answers a critical question: “Is my X-Ray equipment operating at peak performance, or is it time for service?”

Prevent Costly Downtime

Catch issues early before they impact your workflow. Q-Score helps identify underperforming or failing X-Ray devices in real time - saving you from sudden shutdowns or delays in treatment.

Ensure Clinical Accuracy

The higher the Q-Score, the sharper and clearer your diagnostic images - empowering your team to confidently detect conditions and recommend optimal treatment plans.

Maintain Compliance and Consistency

Q-Score provides an objective, digital measure of equipment performance - essential for quality assurance, ministry compliance, and practice standardization.

Save Time, Streamline Operations

No more guesswork. No more waiting for failure. With Q-Score, your team can stay proactive, not reactive.

Start improving your DQA workflow

Choose how you want to begin - get started instantly or book a guided demo.
MVD X-Ray Support